Basic Info.

Model NO.
DF-1.25G-16P-2E-2F
Ports
16
Power Supply Mode
Power Adapter
Power Consumption
The Device <20W,Poe Power Supply <350W
Mac Address List
16K
Switch Capacity
40gbps
Poe Power Supply Mode
End-Span Method
Poe Power Supply Wattage
Each Port Less Than 30W,Whole Device<350W
Weight
4.5kg
Power Indicator Light
One Power Light(Green)
Storage Temperature
-40~ 85c
Working Temperature
-10c~55c
Transport Package
Carton
Specification
442mm× 224mm× 44.5mm
Trademark
Takfly/OEM/Neutral
Origin
Shenzhen, China
HS Code
8517629900
Production Capacity
3500PCS/Week

Product Description

16 port 1000Mbps 1.25G Smart POE optical Ethernet switch
1. Overviews
DF-1.25G-16P-2E-2F is a 20-Port Gigabit PoE Switch with 16 PoE Ports, 2 RJ45 Uplink ports, 2 SFP Gigabit Uplink Optical Ports, port 1 to port 16 supports PoE IEEE 802.3at international standard, each port power is 30W. Total power is 350W.
This POE network switch can meet customer's general demands. POE network switch with POE function, designed for high-definition network camera's internet access. It provides 16 1000Mbps PoE Ethernet switches, complies with IEEE802.3af/at standards, and also simplifies wiring, avoids the troublesome of installing power socket for powered devices.
Typical applications please refer to following picture
1. Features20-Port Gigabit PoE Switch with 16 PoE Ports, 2 RJ45 uplink, 2 SFP Gigabit Uplink Optical PortsSupply power to wireless access points AP and network IP surveillance cameras Port 1 to Port 16 supports IEEE802.3at power (each port maximum power is 30W)16x 10/100/1000 Mbps ports + 2RJ45 + 2x SFP gigabit optical uplink ports Compatible with IEEE 802.3 10i and IEEE 802.3u standardThe packet forwarding speed is 1.488Mbps of one wire-speed portPort features with auto-flip(Auto MDI/MDIX)Network port comes with lighting-proof All ports support wire-speed switching, frame size within the range of 64 to 1536 can achieve wire-speed Standard 1U rack design, suitable for rack installation modeAutomatic adjustment, plug and play, no need software and protocol conversion
 2. HighlightsNo Frame Loss IP Data TransmissionPoE+ Standard 250m in CCTV Mode10 KB Jumbo frames supportFew video time delay4KV Lightning Protection
 3. Products Panel FigureFront panel


 4. Technical Specifications
Item Description
Model DF-1.25G-16P-2E-2F
Power Supply Power Supply Mode  Mains on load
Voltage Range AC 100~240V
Power Consumption The device <20W,                                                        POE power supply <350W
Network Port Parameter Network Ports  1~16 Ports: 10/100/1000Mbps Ethernet port, adaptive control
UPLINK Ethernet port: 10/100/1000Mbps Ethernet port
Uplink SFP:1000Mbp
Transmission Distance 1~16 Ethernet Port:0~100m
Mandatory 10 Mbps reach up to 250m
2 Ethernet Uplink Port:0~100m
2 SFP: According to different SFP
Transmission Media 1~16 Ethernet Port:Cat5e/6 standard UTP cable,
2 Ethernet Uplink Port:Cat5e/6 standard UTP cable
2 SFP: LC interface optical fiber
POE Agreement IEEE802.3 af/at standards
PoE Power Supply Mode End-span method
PoE Power Supply Wattage Each port≤30W,Whole device<350W
Network Switch Specification Network Standard IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX, IEEE802.3ab 1000BASE-T
Swap Mode Store-and- forward
Switch Capacity 40Gbps
MAC Address List 16K
Status Indicators Power Indicator Light One power light (green)
Optical Fiber Port Indicator One fiber link indication light ( green), Green light keeps on when the fiber port is well connected; Blinking when transceiver data
FE Uplink Port LED (Green): On, port is link on; Off, port is link down;
PoE Indicator 1~16 PoE indicator light(yellow)
PoE Network Port LED 1~16 port ( green light on RJ45 jack) Keeps on when normally connected, Blinking when transceiver data
Switch  Switch 1(Vlan 1 to 8) ON: Vlan open, 1 to 8 POE ports only can communicate with uplink port; OFF: Vlan close, normal status
Switch 2(Vlan 9 to 16) ON: Vlan open, 9 to 16 POE ports only can communicate with uplink port, power and data can reach 250 meters;
OFF: Vlan close, normal status
Switch 3 Reserve
Switch 4 Together with switch1 and switch to decide the ports to CCTV mode. If switch4 is on, when switch1 or switch2 open, will open 250 meter CCTV mode; if switch4 is off, when switch1 or switch2 open, will open vlan only.
Protection Level Surge Immunity Level 3, executive standard:IEC61000-4-5
Electrostatic Protection 1a touch electric discharge: level 3                        1a Air discharge: level 3                                Executive standard:IEC61000-4-2
Operating Environment Working Temperature -10ºC~55ºC
Storage Temperature -40ºC-85ºC
Humidity(non-congeal) 0~95%
Mechanical Attributes Dimensions (L*W*H) 442mm×224mm×44.5mm
Color Black
Weight 4.5kg
Reliability Mean time between failures (MTBF) >50000h
Note:
If any changes with product specification, forgive without prior notice.
    As transmission distance has certain relation with the cable, so you are suggested to use standard cat5e/6 cable for longest distance needed. 
5. V-lan6.1 Introduction
    When V-lan function is opened, the LAN port can't make data conversion but can only communicate via uplink port. The V-LAN workstation is built separately between every network port and UP-LINK port.
In the same V-lan workstation, no matter which actual PoE switch being connected, the signal transmission are separately isolated from each other which seems they are on the different switches. The broadcast in the same V-lan can only be received by the members but can't be transmitted into other V-lan, which can greatly control unnecessary broadcast storm. What's more, different V-lan can't even communicate with each other when there is no routing, which increases the safe degree among different department in the enterprise.
5.2 Configuration
   Toggle the V-lan button on the back of the switch to ON state, V-lan indicator lights, then press the reset button to restart the switch, in this way V-lan functions.
Note:
   Please press reset button or repower the device when turn on V-lan, only in this way the switch can enter corresponding mode. 6. InstallationPacking List
Before installation, please check the following equipment and accessories, if there are any missing, please contact with your supplier.
1) 1 set of DF-1.25G-16P-2E-2F
2) 1 AC cable
3) 1 user manual
Please install as below steps
    Before installation, please turn off the power of all signal sources and the monitor in case of the damage to transmission deviceUsing network cables to connect with Ethernet ports of IP cameras and POE ports of PSE-2 series unmanaged POE switchUsing UP-LINK port to connect NVR or computer etc. Device.Check weather installation is correct and the device undamaged. Before power on PSE-2 series unmanaged POE switch, make sure that all connections are reliableConfirm all network devices are powered and can work normally. 
7. TroubleshootingWhen the device encountered with troubles, it can be solved by the methods below:
1) Make sure the device is installed correctly referring to the requirements;
2) Make sure RJ45 cable is good contacted without open circuit; the cable design complies with EIA/TIA568A or 568B international standards.
3) Each PoE port can provides max 30W to switch and the total power is less than the maximum power provided by the device. So please don't connect with the PoE device which is more than 30W.
4) Press reset button to check if the device can work properly.
5) Replace the trouble device with a normal working device to check if the device is damaged.
6) If all the above methods still don't work, please contact with manufacturer directly.
 8. Making methods of RJ45 connectorRequired tools: wire crimpers, network cable tester.
The wire sequence of RJ45l connector must complies with international standard of EIA/TIA 568A or EIA/TIA 568B.
Strip about 2cm's of insulating jacket to let 4 pairs UTP can be seen.
Separate 4 pairs UTP cable, and try to straighten each pair.
Arrange 8 cables with correct line sequence of EIA/TIA 568A or EIA/TIA 568B.
Cut thread residue and leave 1.5cm wire which exposed outside the insulating layer, and ensure 8 wires are straight and neat.
Put 8 wires in RJ 45 connector, then press with wire crimpers.
Repeat above five steps , make the other side of UTP cable; Then using the cable tester to test whether the cat5e/6 works normally.

 

Why choose Takfly ?

Service:
1.Customer's logo: Acceptable
2.General inspection on fixing before packing
3.Third party inspection: Acceptable
 
Quality Control:
All products must go through five checks before manufacturing process
 
1.Material incoming inspection before production
2.Full check after every individual process finished
3.Full check after production half-done
4.Full check before packing
5.Spots check after production packed before shipping
 
Advantage:
1.15 years experience in manufacturing fiber optic products..
2.Availability of R & D with more than 10 engineers.
3.Available of design and making mold with special molding house.
4.High quality, attractive price and fast delivery(2-7days)
5.OEM, ODM customer designs are also welcomed
6.More than 200 worker
7.Excellent service
 
Delivery:
1.Packing: Plastic bag& carton, Neutral packing or as your required.
2.Sample time: 1-3 days after confirmation.
3.Order lead time: 2-7working days depend on quantity and products.
4.Shipping port: Shenzhen, HK or other ports as you required.
5.Shipping term: EXW or FOB




 

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier