Customization: | Available |
---|---|
Type: | Fiber Optic Splitter&Coupler |
Wiring Devices: | ODF |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description:
Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. Takfly provides whole series of 1xN and 2xN splitter products that are tailored for specific applications. All products meet GR-1209-CORE and GR-1221-CORE requirements.
Key Features:
1. Low IL and PDL |
2. High reliability |
3. High channel counts |
4. Wide wavelength range |
5. Large operating temperature range |
6. Excellent Environmental & Mechanical Stability |
Applications:
1. FTTX (FTTP, FTTH, FTTN, FTTC) |
2. Local Area Networks (LAN) |
3. Test Equipment |
4. CATV |
5. Analog/Digital Passive Optical Networks (PON) |
Compliance:
--Telcordia GR-1209 |
--Telcordia GR-1221 |
1×N PLC Splitter Specifications (Measured at room temperature and excludes connector loss)
Port Configuration |
1x2 |
1x4 |
1x8 |
1x16 |
1x32 |
1x64 |
|
Fiber Type |
SMF-28e or customer specified |
||||||
Operating Wavelength (nm) |
1260~1650 |
||||||
Insertion Loss (dB) |
Typical |
3.6 |
6.8 |
10.2 |
13.3 |
16.2 |
20.5 |
Max |
4.0 |
7.4 |
10.5 |
13.5 |
16.9 |
21.0 |
|
Loss Uniformity (dB) |
Max |
0.5 |
0.7 |
1.0 |
1.4 |
1.8 |
2.0 |
Return Loss (dB) |
Min |
55 |
55 |
55 |
55 |
55 |
55 |
Polarization Dependent Loss(dB) |
Max |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
0.4 |
Directivity (dB) |
Min |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
Max |
0.3 |
0.3 |
0.3 |
0.8 |
0.5 |
0.8 |
Temperature Dependent Loss (-40~85 ºC) (dB) |
Max |
0.5 |
0.5 |
0.5 |
0.8 |
0.8 |
1 |
Operating Temperature (ºC) |
-40~+85 |
||||||
Storage Temperature (ºC) |
-40~+85 |
||||||
Packaging Size (mm) |
Fan-Out |
60x7x4 |
60x7x4 |
60x7x4 |
60x12x4 |
80x20x6 |
80x20x6 |
2×N PLC splitter Specifications (Measured at room temperature and excludes connector loss)
Port Configuration |
2x2 |
2x4 |
2x8 |
2x16 |
2x32 |
2x64 |
|
Fiber Type |
SMF-28e or customer specified |
||||||
Operating Wavelength (nm) |
1260~1650 |
||||||
Insertion Loss (dB) |
Typical |
3.8 |
7.4 |
10.8 |
14.2 |
17 |
21 |
Max |
4.2 |
7.8 |
11.2 |
14.6 |
17.9 |
21.5 |
|
Loss Uniformity (dB) |
Max |
1.0 |
1.4 |
1.5 |
2 |
2.5 |
2.5 |
Return Loss (dB) |
Min |
50 |
50 |
50 |
50 |
50 |
50 |
Polarization Dependent Loss(dB) |
Max |
0.2 |
0.2 |
0.4 |
0.4 |
0.4 |
0.5 |
Directivity (dB) |
Min |
55 |
55 |
55 |
55 |
55 |
55 |
Wavelength Dependent Loss(dB) |
Max |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
1 |
Temperature Dependent Loss (-40~85 ºC) (dB) |
Max |
0.5 |
0.5 |
0.8 |
0.8 |
1 |
|
Operating Temperature (ºC) |
-40~+85 |
||||||
Storage Temperature (ºC) |
-40~+85 |
||||||
Packaging Size (mm) |
Fan-Out |
60x7x4 |
80x12x4 |
80x12x4 |
80x20x6 |
Remark:The above IL is for the PLC Splitter without connectors,for the PLC Splitter with connectors, the above IL should add 0.3dB each
Environmental Conditions
Operating Temperature |
ºC |
-40~+85' |
Storage Temperature |
ºC |
-40~+85 |
Operating Humidity |
%RH |
≤93 |
Storage Humidity |
%RH |
≤93 |